Skip to main content

Published Release Notes

Find release notes for the selected Pega Version and Capability

Browse resolved issues for Platform releases.

Data synchronization does not resume after mobile app restart

Valid from Pega Version 8.3

If an offline-enabled mobile app that you build with Pega Infinity Mobile Client is stopped during an initial data synchronization session, the data synchronization does not resume when the mobile app is restarted. Users must not stop the mobile app before initial data synchronization finishes.

For more information about data synchronization, see Offline capability and Guidelines for creating an offline-enabled application.

Mobile features deprecated in 8.4

Valid from Pega Version 8.4

Following the introduction of new functionalities for mobile apps, some features are reaching end of life. To avoid additional effort during updates to future releases, do not use deprecated features.

In the 8.4 release, the following features are no longer recommended:

  • Mobile Client 7 is now deprecated and planned for removal in 8.5. Use Pega Infinity Mobile Client to meet the mobile needs of your business.
  • The Reuse existing web portal functionality is deprecated and planned for removal in 8.5. For improved app performance and more efficient development, use the mobile app builder in the mobile channel. Also, you must convert existing projects to use separate channels for mobile and web portals before upgrading to 8.5.

In addition, the Pega Mobile Express app has been removed from app stores and replaced with the Pega Mobile Preview app.

Limited access for end user portals

Valid from Pega Version 7.1.1

The following portals are only accessible from supported versions of Internet Explorer in “quirks” mode:

  • WorkUser
  • WorkManager

Cannot copy final section rules in UI Kit ruleset

Valid from Pega Version 7.1.6

You cannot copy section rules in the UI Kit ruleset (UI-Kit-71) that start with pz or px (final rules in the base PRPC rulesets).

Instead, to customize these rules, use the Copy/Merge Ruleset tool, available at Designer Studio >System > Tools > Refactor Rulesets, to copy all rules from the UI Kit into your application ruleset. You can then check the section rules in and out.

Nesting dynamic containers not supported

Valid from Pega Version 7.1.1

Do not include a section containing a dynamic container inside of another dynamic container. This configuration may cause performance issues resulting in unexpected behavior at runtime, and is not supported.

Text Input control number type does not validate

Valid from Pega Version 7.1.5

When a Text Input control type is set to "Number" in the Presentation tab:

  • Validation does not trigger and the field is blanked out when a user submits the form.
  • If a value other than a number is entered, the browser sends an empty value, and the value is not validated.
  • In the Clipboard, the field value displays as empty.
  • If the field is required, the validation displays.

This issue occurs when using both the Chrome and Safari web browsers, and is a result of browser behavior for the HTML5 type=“number”. To fix this issue when using these browsers, do not use the "Number" type in Presentation tab of a Text Input control. Instead, the type should be set to "Text".

Offline mobile apps require Dynamic Container to use frameless Single Document mode

Valid from Pega Version 7.1.7

You can add a Dynamic Container (DC) directly into a Dynamic Layout cell. When creating a custom mobile app with offline capability, you must use the frameless Single Document mode of DC.

Note that mobile offline capability does not support using a framed Single Document mode.

Unclear error message when saving shared class instance in tenant layer

Valid from Pega Version 7.1.5

If you attempt to save a shared class instance from the tenant layer, Pega 7 displays this message:

This record has x errors. Save Failed: There was a problem saving an instance of class: Error Code: <none> SQL State: <none> Message: <none>

You cannot save a shared instance from the tenant layer if that instance cannot be overridden.

Microsof Internet Explorer 9 (IE9) may display a script error when clicking a Help button

Valid from Pega Version 7.1.6

A script error may be displayed when clicking a Help button when script error notification is turned on in the browser. As a work around, uncheck the Display a notification about every script error option in the Advanced tab of the Options dialog box in Microsoft Internet Explorer 9.

Number and text input controls on Android devices may not display the correct keyboard

Valid from Pega Version 7.1.8

When running a Pega 7 application on a device using the Android operating system, pxNumber and pxTextInput controls may not display when using the desired on-screen keyboard. This happens when the number or text input type is set to number.

At design time, the input type is selected in the Editable Format section of the Presentation tab in the Cell Properties panel for a pxNumber or pxTextInput control. Due to a known limitation in some versions of the Android OS running on some devices, the keyboard displayed at run time may not support entry of decimal values when a Number type keyboard is specified.

To resolve this issue, use the Phone type when numbers with decimal values may be required. Using the Phone type displays a numerical phone keyboard. The Android phone keyboard includes both commas and periods so that decimals may be entered.

Cell Properties dialog

The Phone type selected in the Presentation tab of a Number control

Note that this issue only occurs on Android devices. It is recommended that applications for iOS continue to use type=“Number”.

Ready to crush complexity?

Experience the benefits of Pega Community when you log in.

We'd prefer it if you saw us at our best.

Pega.com is not optimized for Internet Explorer. For the optimal experience, please use:

Close Deprecation Notice
Contact us