Skip to main content

Published Release Notes

Find release notes for the selected Pega Version and Capability

Browse resolved issues for Platform releases.

This documentation is for non-current versions of Pega Platform. For current release notes, go here.

Text Input control number type does not validate

Valid from Pega Version 7.1.5

When a Text Input control type is set to "Number" in the Presentation tab:

  • Validation does not trigger and the field is blanked out when a user submits the form.
  • If a value other than a number is entered, the browser sends an empty value, and the value is not validated.
  • In the Clipboard, the field value displays as empty.
  • If the field is required, the validation displays.

This issue occurs when using both the Chrome and Safari web browsers, and is a result of browser behavior for the HTML5 type=“number”. To fix this issue when using these browsers, do not use the "Number" type in Presentation tab of a Text Input control. Instead, the type should be set to "Text".

Unclear error message when saving shared class instance in tenant layer

Valid from Pega Version 7.1.5

If you attempt to save a shared class instance from the tenant layer, Pega 7 displays this message:

This record has x errors. Save Failed: There was a problem saving an instance of class: Error Code: <none> SQL State: <none> Message: <none>

You cannot save a shared instance from the tenant layer if that instance cannot be overridden.

Set a time zone for the DateTime control

Valid from Pega Version 8.3

The DateTime control now supports the selection of a specific time zone. Apart from the default local time zone, you can choose a Java-supported time zone or enter a property. For example, you can make it easier for a manager working in New York to schedule a task for a worker in London by configuring a calendar picker on user forms to show a date and time for Europe/London.

Beginning with this release, the calendar picker defaults to the current time in the time zone that is defined in the operator record. Previously, it defaulted to the local time zone of the system.

For more information, see Specifying a time zone for a DateTime control.

Upgrade impact

After a successful upgrade, the DateTime gadget displays the time in the current operator's locale, which is defined on the operator rule form or in the browser.  

What steps are required to update the application to be compatible with this change?

If you need to display the system time from which the user has logged in, and if this is not the same as the time in the user's locale (based on the browser setting), set the Locale field in the operator ID to be blank so that the browser-based setting and the displayed time are the same as the system time.