Derby databases are no longer supported
Valid from Pega Version 7.1.8
Previously, an embedded Derby database could be used as a file system. This setup was configured by setting storage/class/<<filesystem>>/type to "embedded" in the prconfig
file.
After upgrading, storage types that are specified as "embedded" now default to the local file system.
JavaMail API upgrade has potential SMTP configuration error
Valid from Pega Version 7.1.8
The JavaMail API has been upgraded from 1.4.1 to 1.5.2 in this release. This improvement provides greater compatibility and secure connectivity with leading industry email servers.
During the upgrade process, there is a known issue for some configurations of email servers, including Microsoft Exchange Server, that requires the use of an additional setting. After upgrading to this release, if you experience authentication failures when attempting to send email or test SMTP connectivity, do one of the following:
- Recommended: Review the Microsoft Exchange email server settings to ensure proper configuration for SMTP authentication. In some cases, the use of port 587 instead of the traditional default SMTP port 25 has been shown to address this issue.
- Create the following Dynamic System Setting with the value "true," and then restart email listeners:
Owning Ruleset: Pega-IntegrationEngine
Setting Purpose: javamail/NoAuthMechanismsRetry
After any email server configuration or upgrade, it is recommended that email listeners are re-tested without using this Dynamic System Setting.
See About Email Account data instances for information on configuring email account records.
The Create Build button appears grayed out when configuring and building a mobile application
Valid from Pega Version 7.1.8
When you attempt to configure and build your Android or iOS mobile application from the Mobile tab, the button might appear dimmed. This issue occurs if any of the access roles in the access group were cloned from the PegaRULES:SysAdm4 access role.
Refer to Troubleshooting Pega Mobile Client to learn how to fix this issue in your application.
Decision Data Store data sets can be used only on DNodes
Valid from Pega Version 7.1.8
Data flows that contain Decision Data Store data sets as the primary or secondary source must be created and executed only on DNodes.
Data flows are not restarted automatically after application server restart
Valid from Pega Version 7.1.8
When you restart the application server or the Pega 7 server, you stop the execution of your data flows. The interrupted batch and real-time runs are marked as Failed.
Recommendation:
- Go to the > > > > tab and start the failed batch runs.
-
Go to the
> > > > tab and activate the failed real-time runs.
Value list and value group properties are not supported inside data flows
Valid from Pega Version 7.1.8
Value list and value group properties are not supported inside data flows, and you need to instead use other property types.
See the Pega 7 developer help to check all available property types.
Data flow preview size is fixed to 10
Valid from Pega Version 7.1.8
The Preview option for each shape in data flows returns the first 10 records. This value is fixed and currently cannot be changed.
Data Flow transformation shapes cannot be used in combination with the Compose or Merge shapes
Valid from Pega Version 7.1.8
When you reference another data flow from a data flow that contains the Compose or shape, the referenced data flow cannot contain transformation shapes ( , , ).
Data flow validation does not currently prevent you from designing a data flow that goes against this design pattern. Make sure that your data flows follow this design pattern by checking the referenced and referencing data flows.
Data flow destination is resolved at assembly time
Valid from Pega Version 7.1.8
Data flow execution always uses the design-time destination data sets or destination data flows, regardless of the input records at run time.
Example:
You create a data flow and set the destination to a specific data set. In the data flow, you use a strategy that produces some results. Regardless of these results, the execution of your data flow always uses the destination data set that you specified when you designed the data flow.
The same applies when you set the destination to a data flow.
Offline configuration limitation
Valid from Pega Version 7.1.8
When enabling the offline capability for a case type, do not select the Enable offline check box in Case Designer because it incorrectly sets the locking strategy. Instead, select the Enable offline mode check box on the Advanced tab of the Case Type form.
To open the Case Type form from Case Designer, click Open on the menu.