Skip to main content

Published Release Notes

Find release notes for the selected Pega Version and Capability

Browse resolved issues for Platform releases.

This documentation is for non-current versions of Pega Platform. For current release notes, go here.

JavaMail API upgrade has potential SMTP configuration error

Valid from Pega Version 7.1.8

The JavaMail API has been upgraded from 1.4.1 to 1.5.2 in this release. This improvement provides greater compatibility and secure connectivity with leading industry email servers.

During the upgrade process, there is a known issue for some configurations of email servers, including Microsoft Exchange Server, that requires the use of an additional setting. After upgrading to this release, if you experience authentication failures when attempting to send email or test SMTP connectivity, do one of the following:

  • Recommended: Review the Microsoft Exchange email server settings to ensure proper configuration for SMTP authentication. In some cases, the use of port 587 instead of the traditional default SMTP port 25 has been shown to address this issue.
  • Create the following Dynamic System Setting with the value "true," and then restart email listeners:

Owning Ruleset: Pega-IntegrationEngine

Setting Purpose: javamail/NoAuthMechanismsRetry

After any email server configuration or upgrade, it is recommended that email listeners are re-tested without using this Dynamic System Setting.

See About Email Account data instances for information on configuring email account records.

Decision Data Store data sets can be used only on DNodes

Valid from Pega Version 7.1.8

Data flows that contain Decision Data Store data sets as the primary or secondary source must be created and executed only on DNodes.

Data flows are not restarted automatically after application server restart

Valid from Pega Version 7.1.8

When you restart the application server or the Pega 7 server, you stop the execution of your data flows. The interrupted batch and real-time runs are marked as Failed

Recommendation:

  • Go to the Designer StudioDecisioning > Decisions > Data Flows > Batch processing tab and start the failed batch runs.
  • Go to the Designer StudioDecisioning > Decisions > Data Flows > Real-time processing tab and activate the failed real-time runs.

 

Value list and value group properties are not supported inside data flows

Valid from Pega Version 7.1.8

Value list and value group properties are not supported inside data flows, and you need to instead use other property types.

See the Pega 7 developer help to check all available property types.

Data flow preview size is fixed to 10

Valid from Pega Version 7.1.8

The Preview option for each shape in data flows returns the first 10 records. This value is fixed and currently cannot be changed.

Data Flow transformation shapes cannot be used in combination with the Compose or Merge shapes

Valid from Pega Version 7.1.8

When you reference another data flow from a data flow that contains the Compose or Merge shape, the referenced data flow cannot contain transformation shapes (EventStrategy, Decision strategy, Convert).

Data flow validation does not currently prevent you from designing a data flow that goes against this design pattern. Make sure that your data flows follow this design pattern by checking the referenced and referencing data flows.

 

Data flow destination is resolved at assembly time

Valid from Pega Version 7.1.8

Data flow execution always uses the design-time destination data sets or destination data flows, regardless of the input records at run time.

Example:

You create a data flow and set the destination to a specific data set. In the data flow, you use a strategy that produces some results. Regardless of these results, the execution of your data flow always uses the destination data set that you specified when you designed the data flow.    

The same applies when you set the destination to a data flow.

 

 

Creating data page unit tests in Internet Explorer 8

Valid from Pega Version 7.1.8

When creating data page unit tests, selecting a parent property does not automatically select the child properties when using Internet Explorer 8.

Page and page list properties to be included in a data page unit test are selected on the Create test screen by selecting a check box next to the property name. Normally, selecting the check box of a parent property automatically selects all subsequent child properties as well. When using Internet Explorer 8, child properties are not automatically selected when the parent property's check box is selected.

The solution requires selecting all of the desired child properties individually. Select the check box next to each child property to include it in the data page unit test.

Extension attributes are not supported in PMML models

Valid from Pega Version 7.3.1

Models in the Predictive Model Markup Language (PMML) format version 4.3 that contain extension attributes with the x- prefix are not valid. These extension attributes are deprecated; you must use extension elements instead. In addition, if the output type of any output field in the model is set to FLOAT, change it to DOUBLE.

For more information, see PMML 4.3 - General Structure in the Data Mining Group documentation.

Precision of Oracle Timestamp property when using RDB-Save

Valid from Pega Version 7.1.8

DateTime properties that are mapped to an Oracle Timestamp column will experience a loss of precision when they are saved using the RDB-Save method. When you use RDB-Save for an Oracle Timestamp, precision will be accurate to the second. For example, a value of 20171119T124745.006 will be saved as 20171119T124745. When you use Obj-Save, precision will be accurate to the millisecond. For more information, see DateTime property mapping in Oracle for Pega 7.

We'd prefer it if you saw us at our best.

Pega.com is not optimized for Internet Explorer. For the optimal experience, please use:

Close Deprecation Notice
Contact us