Derby databases are no longer supported

Valid from Pega Version 7.1.8

Previously, an embedded Derby database could be used as a file system. This setup was configured by setting storage/class/<<filesystem>>/type to "embedded" in the prconfig file.

After upgrading, storage types that are specified as "embedded" now default to the local file system.

JavaMail API upgrade has potential SMTP configuration error

Valid from Pega Version 7.1.8

The JavaMail API has been upgraded from 1.4.1 to 1.5.2 in this release. This improvement provides greater compatibility and secure connectivity with leading industry email servers.

During the upgrade process, there is a known issue for some configurations of email servers, including Microsoft Exchange Server, that requires the use of an additional setting. After upgrading to this release, if you experience authentication failures when attempting to send email or test SMTP connectivity, do one of the following:

  • Recommended: Review the Microsoft Exchange email server settings to ensure proper configuration for SMTP authentication. In some cases, the use of port 587 instead of the traditional default SMTP port 25 has been shown to address this issue.
  • Create the following Dynamic System Setting with the value "true," and then restart email listeners:

Owning Ruleset: Pega-IntegrationEngine

Setting Purpose: javamail/NoAuthMechanismsRetry

After any email server configuration or upgrade, it is recommended that email listeners are re-tested without using this Dynamic System Setting.

See About Email Account data instances for information on configuring email account records.

Creating data page unit tests in Internet Explorer 8

Valid from Pega Version 7.1.8

When creating data page unit tests, selecting a parent property does not automatically select the child properties when using Internet Explorer 8.

Page and page list properties to be included in a data page unit test are selected on the Create test screen by selecting a check box next to the property name. Normally, selecting the check box of a parent property automatically selects all subsequent child properties as well. When using Internet Explorer 8, child properties are not automatically selected when the parent property's check box is selected.

The solution requires selecting all of the desired child properties individually. Select the check box next to each child property to include it in the data page unit test.

Configuration required for data operations on external schema when using a Postgres database

Valid from Pega Version 7.1.8

When you use the API for data operations on external schema in the Postgres database, you must update the prconfig.xml file. No other platform requires a prconfig.xml update.

To update the prconfig.xml file:

  1. Stop the server and add the following entry to the prconfig.xml file:
    env name="database/databases/postgres_ext/defaultSchema"
    value="externalschema"
    where postgres_ext is the external database that uses the external schema “externalschema”.
  2. Restart the server.

Pega File Listener process changes

Valid from Pega Version 7.2.2

Beginning with Pega 7.2.2, File Listener processes files in a different way:

  • File movement in directories – Previously, files were processed from the Work directory. In Pega 7.2.2, files are processed from the source location. Files move to the Work directory only if the initial processing fails and Recovery is disabled.
  • New file processing – Previously, File Listener would process all files in the source location, even if the files were added during the processing. In Pega 7.2.2, files added to the source location during processing are read the next time the File Listener starts.

For more information, see File Listener data instances.

Functionality of the pyInvokeRESTConnector rule and the pxDeferenceEndpoint rule moved to core engine

Valid from Pega Version 7.2.2

The functionality of the pyInvokeRESTConnector rule and the pxDeferenceEndpoint rule has been moved into the core engine code of the Pega 7 Platform. This change provides more consistent behavior, reduces maintenance, and reduces the risk of regression issues. As a result, you can no longer customize these rules, and upgrading the Pega 7 Platform requires special considerations if you previously customized these rules.

For more information, see Upgrading with customized pyInvokeRESTConnector and pxDeferenceEndpoint rules.

Precision of Oracle Timestamp property when using RDB-Save

Valid from Pega Version 7.1.8

DateTime properties that are mapped to an Oracle Timestamp column will experience a loss of precision when they are saved using the RDB-Save method. When you use RDB-Save for an Oracle Timestamp, precision will be accurate to the second. For example, a value of 20171119T124745.006 will be saved as 20171119T124745. When you use Obj-Save, precision will be accurate to the millisecond. For more information, see DateTime property mapping in Oracle for Pega 7.

Support for character data type on local variables in activities deprecated

Valid from Pega Version 8.1

Support for the character data type for local variables in activities is deprecated. Use the string data type instead.

For more information about activities, see Activities.

When rule might not resolve against @baseclass

Valid from Pega Version 8.1

In the rare case in which a step page context is null, or the pxObjClass associated with the step page is empty, the system no longer attempts to resolve the when rule against @baseclass. As a result, you might see more rule not found errors. Check the step page context and class and ensure that they are not null or empty. In all other cases, if a when rule is not found in any other part of the class hierarchy, the system attempts to resolve it against @baseclass.

For Microsoft SQL Server deployments, change settings to create data types in Integration Designer

Valid from Pega Version 8.1

For on-premises deployments that use Microsoft SQL Server, set the Pega-Reporting/reporting/useMergeHintForRRquery dynamic system setting to true. If you do not configure this setting, you might not be able to create a new data type in Integration Designer that uses Pega as the system of record. Configure the setting as follows:

  • Owning ruleset: Pega-Reporting
  • Setting purpose: reporting/useMergeHintForRRquery
  • Value: true

For more information about configuring dynamic system settings, see Creating a dynamic system setting.