Skip to main content

Published Release Notes

Find release notes for the selected Pega Version and Capability

Browse resolved issues for Platform releases.

Derby databases are no longer supported

Valid from Pega Version 7.1.8

Previously, an embedded Derby database could be used as a file system. This setup was configured by setting storage/class/<<filesystem>>/type to "embedded" in the prconfig file.

After upgrading, storage types that are specified as "embedded" now default to the local file system.

JavaMail API upgrade has potential SMTP configuration error

Valid from Pega Version 7.1.8

The JavaMail API has been upgraded from 1.4.1 to 1.5.2 in this release. This improvement provides greater compatibility and secure connectivity with leading industry email servers.

During the upgrade process, there is a known issue for some configurations of email servers, including Microsoft Exchange Server, that requires the use of an additional setting. After upgrading to this release, if you experience authentication failures when attempting to send email or test SMTP connectivity, do one of the following:

  • Recommended: Review the Microsoft Exchange email server settings to ensure proper configuration for SMTP authentication. In some cases, the use of port 587 instead of the traditional default SMTP port 25 has been shown to address this issue.
  • Create the following Dynamic System Setting with the value "true," and then restart email listeners:

Owning Ruleset: Pega-IntegrationEngine

Setting Purpose: javamail/NoAuthMechanismsRetry

After any email server configuration or upgrade, it is recommended that email listeners are re-tested without using this Dynamic System Setting.

See About Email Account data instances for information on configuring email account records.

Creating data page unit tests in Internet Explorer 8

Valid from Pega Version 7.1.8

When creating data page unit tests, selecting a parent property does not automatically select the child properties when using Internet Explorer 8.

Page and page list properties to be included in a data page unit test are selected on the Create test screen by selecting a check box next to the property name. Normally, selecting the check box of a parent property automatically selects all subsequent child properties as well. When using Internet Explorer 8, child properties are not automatically selected when the parent property's check box is selected.

The solution requires selecting all of the desired child properties individually. Select the check box next to each child property to include it in the data page unit test.

Configuration required for data operations on external schema when using a Postgres database

Valid from Pega Version 7.1.8

When you use the API for data operations on external schema in the Postgres database, you must update the prconfig.xml file. No other platform requires a prconfig.xml update.

To update the prconfig.xml file:

  1. Stop the server and add the following entry to the prconfig.xml file:
    env name="database/databases/postgres_ext/defaultSchema"
    value="externalschema"
    where postgres_ext is the external database that uses the external schema “externalschema”.
  2. Restart the server.

Precision of Oracle Timestamp property when using RDB-Save

Valid from Pega Version 7.1.8

DateTime properties that are mapped to an Oracle Timestamp column will experience a loss of precision when they are saved using the RDB-Save method. When you use RDB-Save for an Oracle Timestamp, precision will be accurate to the second. For example, a value of 20171119T124745.006 will be saved as 20171119T124745. When you use Obj-Save, precision will be accurate to the millisecond. For more information, see DateTime property mapping in Oracle for Pega 7.

Ready to crush complexity?