Naming pattern changed for file data sets

Valid from Pega Version 8.6.3

File data sets are used to import from and export data to a file repository. In case of data export, prior to version 8.6.3, the first file exported had the same file name that was provided by the user in the data set, and any subsequent file exported to the repository had a unique identifier appended to it. Starting in Pega Platform version 8.6.3, each file has a unique identifier, automatically generated based on the data flow node, thread ID, and timestamp.

Upgrade impact

If your process to consume output files expects files with a specific name, it may not be able to process the resulting files correctly.

What steps are required to update the application to be compatible with this change?

If you have configured the process before updating to Pega Platform version 8.6.3, but the exported files are no longer recognized by downstream processing logic after the upgrade, ensure that the downstream tool is configured to recognize the files by a pattern rather than the full name. For example, when referring to files exported to the repository, use the * character to indicate a pattern instead of using the full file name. For example, use Export*.csv to refer to the files.

Interactions in flows are no longer supported by the Run Interaction shape

Valid from Pega Version 7.3.1

The Run Interaction shape in flows has been replaced by the Run Data Flow shape, which supports running a single case data flow with a strategy. Flows that include the Run Interaction shape continue to work; however, you must now use the Utility shape to reference any new interactions that you create.

For more information, see Running a decision strategy from a flow and About Interaction rules.

Extension attributes are not supported in PMML models

Valid from Pega Version 7.3.1

Models in the Predictive Model Markup Language (PMML) format version 4.3 that contain extension attributes with the x- prefix are not valid. These extension attributes are deprecated; you must use extension elements instead. In addition, if the output type of any output field in the model is set to FLOAT, change it to DOUBLE.

For more information, see PMML 4.3 - General Structure in the Data Mining Group documentation.

The Upload responses action is not supported for adaptive models with customized context

Valid from Pega Version 7.3.1

A default instance of the Adaptive Model rule contains five model identifiers (.pyIssue, .pyGroup, .pyName, .pyDirection, .pyChannel) that are used to partition adaptive models. If you add other identifiers in your Adaptive Model rule instance, you cannot upload responses to this instance with the Upload Responses wizard and the following error is displayed: The Flow Action post-processing activity pzUploadCSVFile failed: Cannot parse csv file.You can still train such adaptive models with data flows.

For more information, see Training adaptive models in bulk with data flows, Model context, and Uploading customer responses.

Upgrading Adaptive Decision Manager data mart tables might fail

Valid from Pega Version 7.3.1

Issue: Upgrade from 7.3 to 7.3.1 fails if the data contained in the pxInsName column of the PR_DATA_DM_ADMMART_PRED_FACT table is longer than 128 characters.

Reason: During the Pega Platform™ upgrade from 7.3 to 7.3.1, data in the Adaptive Decision Manager (ADM) data mart tables is migrated from the PR_DATA_DM_ADMMART_PRED_FACT table to the PR_DATA_DM_ADMMART_MDL_FACT table. In Pega 7.3.1, ADM uses only the PR_DATA_DM_ADMMART_MDL_FACT table where the pxInsName property can store values that are 128 characters long. In Pega Platform 7.3, the pxInsName property in the PR_DATA_DM_ADMMART_PRED_FACT table can store values that are 255 characters long. If the pxInsName property contains values that are longer that 128 characters, the upgrade fails.

Resolution: Issue an ALTER TABLE statement to change the pxInsName column size to 255 characters and resume the upgrade. For example:

ALTER TABLE rules.pr_data_dm_admmart_pred ALTER COLUMN pxInsName TYPE varchar(255);

For more information, see Adaptive Decision Manager data model.