Skip to main content

Published Release Notes

Find release notes for the selected Pega Version and Capability

Browse resolved issues for Platform releases.

Flow rules not supported in IE8

Valid from Pega Version 7.1.1

In versions prior to 7.1.2, flow rules do not open in Internet Explorer 8 (IE8). Upgrade your system to the latest version of PRPC or access flows from another supported browser.

Word merge support with Microsoft Silverlight plug-in

Valid from Pega Version 7.1.3

PRPC features that integrate with the Word merge capability are now cross-browser. ActiveX controls (which are only compatible with IE) have been replaced with Microsoft Silverlight. This plug-in must be downloaded separately from Microsoft, as it is not shipped with PRPC.

Some common PRPC features affected by this change include the Application Document Wizard, App Profile, Specifications Landing Page, Specification form, and Case Type Landing Page.

Prior to using these features, Users of PRPC 7.1.3 need to set up their client system(s) as follows:

1. Install Silverlight plug-in

Follow the PRPC prompt to install Silverlight when you attempt to use the Word merge feature:

Silverlight1.jpg

Or download package directly: www.microsoft.com/silverlight/

2. Install PRPC prerequisites

Microsoft Internet Explorer (IE) browsers automatically detect the need for PRPC prerequisites and will prompt for install:

Silverlight2.jpg

Non-IE browsers will load a pop-up window when the user attempts to use the Word merge feature.  Use the link to manually download PRPC prerequisites:

Silverlight3.jpg

Extract the .zip file, execute setup.exe and follow the install wizard:

Silverlight4.jpg

Administrators setting up multiple clients at once may refer to the pzSLpreReqs.cab available in the PRPC 7.1.3 resource kit.

3. Restart browser

Log out of PRPC, close all open sessions and restart your browser.

The PRPC feature integrated with Word merge is now ready for use; Silverlight prompts are no longer displayed.

4. Troubleshooting

Silverlight installation requires access to your file system and a registry setting update to “trust” the associated Verisign certificate.  Contact your administrator if you encounter any security or permission errors during this process.

While Silverlight is cross-browser, it is not fully cross-platform.  Mac users may use Word merge features in Chrome via Parallels.

See the PRPC Developer Help for more information on browser setup requirements.

Organization Setup superseded by New Application Wizard

Valid from Pega Version 7.1.3

The Organization Setup Wizard has been retired in PRPC 7.1.3.  This feature was previously launched from the Designer Studio > Org & Security > Organization > Organization Setup menu. Users are encouraged to run the New Application Wizard (also known as Application Express) instead:

NewAppWizard.jpg

This tool quickly generates an application along with all of the artifacts previously offered by the Organization Setup Wizard. This includes, but is not limited to, the class hierarchy, application rule, organization/division/unit rules, and all relevant data instances.

See the following PDN article for more details on the New Application Wizard:

Create new applications quickly and easily with Application Express

Enabling security policies now requires current password

Valid from Pega Version 7.1.3

As part of Pega’s initiative to protect against malicious attacks, the change password dialog has been enhanced.  When Security Policies have been enabled for your system, new users or those with expired passwords will now be prompted for both their existing password as well as their desired new password.

For more details, review the Designer Studio > System > Settings > Security Policies landing page.

Supported JDBC drivers

Valid from Pega Version 7.1.1

Pega 7.1.1 supports Java 6 and Java 7 SDKs only. Ensure that the JDBC driver you are using supports those versions of Java. See your database installation or upgrade documentation for additional information.

DatabaseJava 6Java 7
Oracleojdbc6.jarojdbc7.jar
MSQLsqljdbc4.jarsqljdbc4.jar
DB2 LUWdb2jcc4.jardb2jcc4.jar
DB2 z/OS*db2jcc4.jar or jdb2jcc.jar**db2jcc4.jar
PostgreSQLpostgresql-9.1-903.jdbc4.jar***postgresql-9.1-903.jdbc4.jar

* JDBC drivers are only available from the DB2 for z/OS product. Additionally, you need db2jcc_license_cisuz.jar in the same directory as db2jcc4.jar.

** The db2jcc.jar has been deprecated and may not be supported in future releases.

*** This .jar file is required for PostgreSQL version 9.1.x.

Remove JVM settings from prior installations

Valid from Pega Version 7.1.1

JVM memory settings ​defined in the setupDatabase.properties file to support a prior installation need to be removed. 

Memory settings are now handled by the installation program. Duplicating these settings may cause installation or upgrade failures. 

Privilege required for Recent Explorer

Valid from Pega Version 7.1.1

Users with custom roles defined must add the pxUpdateRecents privilege to see work in the Recent Items Explorer. 

Deprecated end user portals

Valid from Pega Version 7.1.1

The following portals are no longer be supported:

  • SysAdmDD
  • WorkUserDD
  • WorkManagerDD

As a best practice, customize standard, supported portals rather than update your existing portals to include new features.

Split schema upgrade instructions missing properties

Valid from Pega Version 7.1.3

If you upgraded from 5.x, 6.x, or 7.x using the instructions in previous versions of the upgrade guide, you may have neglected to set the properties below in your migrateSystem.properties file when you migrated your upgraded schema to the source system:

 

pega.rules.objects.generate=true

pega.rules.objects.apply=true

 

If these properties were not set during an upgrade that splits the schema, your environment does not have the indexes, triggers, and primary keys on the rules tables.

 

To check for this issue, see if the pr4_base and pr4_rule rules tables in your existing rules schema are missing primary keys. If they are, use the SQL scripts in the ResourceKit\MigrationRecoveryScripts directory of the release to cleanup duplicate rules that were created due to this issue. Follow the steps below to run the scripts.

To run the scripts on Microsoft SQL, Oracle, or PostgreSLQ

  1. Take down any app servers using the affected schema.
  2. Backup your database.
  3. Replace all instances of @RULES_SCHEMA in <database>_cleanDups.sql with the name of the schema that contains the pr4_base table.
  4. Run the <database>_cleanDups.sql script on the database with vendor tools (sqlPlus, SQL Server Management Studio, etc).
  5. Replace all instances of @RULES_SCHEMA in <database>_fix_vw_table.sql with the name of the schema that contains the pr4_base table.
  6. Run the <database>_fix_vw_table.sql script on the database with vendor tools (sqlPlus, SQL Server Management Studio, etc).
  7. Generate and apply the ddl using the command line generateDDL command. Check the installation guide for your database or the upgrade guide for details about how to use the generateDDL command line script.
  8. Rebuild the indexes for the tables in your rules schema using vendor tools. This is necessary so that your system runs at an optimum speed.
  9. Optionally upgrade to the latest release, at this point your database is ready to be upgraded or used depending on your needs.

      

To run the scripts on DB2 for LUW or z/OS

  1. Take down any app servers using the affected schema.
  2. Backup your database.
  3. Run the <database>_cleanDups.sql script on the database with vendor tools (UDB CLP, Data Studio, etc) to create the CLEANSE_RULES_DUPS stored procedure.
  4. Run the query Call CLEANSE_RULES_DUPS(‘<rulesSchema>’); where <rulesSchema> is the name of schema that contains the pr4_base table.
  5. After the previous step is complete drop the CLEANSE_RULES_DUPS procedure.
  6. Replace all instances of @RULES_SCHEMA in <database>_fix_vw_table.sql with the name of the schema that contains the pr4_base table.
  7. Run the <database>_fix_vw_table.sql script on the database with vendor tools (UDB CLP, Data Studio, etc).
  8. Generate and apply the ddl using the command line generateDDL command. Check the installation guide for your database or the upgrade guide for details about how to use the generateDDL command line script.
  9. Rebuild the indexes for the tables in your rules schema using vendor tools. This is necessary so that your system runs at an optimum speed.
  10. Optionally upgrade to the latest release. At this point your database is ready to be upgraded or used depending on your needs.

Required DB2 settings for LUW and z/OS

Valid from Pega Version 7.1.1

Installations on DB2 databases for LUW and z/OS require a minimum logging file size (4096) and a default table space page size (32K).

To set the table space page size to 32K:

  1. Stop the system.
  2. Rename one table (“TableX”) to backup (“TableXBackup”).
  3. Create a new table space that uses a 32K page size.
  4. Copy “TableXBackup” to “TableX” in the new table space.
  5. Restart the system and test to verify there are no issues.
  6. Drop the backup table (or keep it for future reference).

Additional information is available in the "Adjusting the log space size in upgraded databases" article: https://pic.dhe.ibm.com/infocenter/db2luw/v9r7/index.jsp?topic=%2Fcom.ibm.db2.luw.qb.upgrade.doc%2Fdoc%2Ft0023289.html

Ready to crush complexity?

Experience the benefits of Pega Community when you log in.

We'd prefer it if you saw us at our best.

Pega.com is not optimized for Internet Explorer. For the optimal experience, please use:

Close Deprecation Notice
Contact us