Default value of the threadpoolsize agent affects batch indexing

Valid from Pega Version 8.5.2

After you patch Pega Platform to version 8.5.2 or higher, the system changes the default value of the threadpoolsize agent, which controls the number of concurrent activities (threads) in the system, from 5 to 15. Batch indexing in Pega Platform does not require all 15 threads, so you can change the agent value to increase system performance by managing the indexing/distributed/batch/numworkers dynamic system setting.
If your deployment does not support that setting, and batch indexing does not use Queue Processors, the system uses the threadpoolsize value for batch indexing instead.

For more information, see Editing a dynamic system setting.

DCO and PMF integration is unavailable

Valid from Pega Version 7.1.5

DCO and PMF integration functionality is not available in this release. Related project management controls have been removed from the following:

  • System Settings landing page (Designer Studio > System > Settings > Project Management)
  • Application Profile landing page (Designer Studio > Application > Profile > Specifications)
  • Add/Edit Specification dialog

Restricted SMA access

Valid from Pega Version 7.1.5

System Management Application (SMA) remote connections are not supported on JBoss EAP 6.x. This means SMA users may only monitor locally connected systems. Ensure that the "Local JVM Connection..." option is selected when configuring PRPC nodes:

Stages and Steps may not appear as expected

Valid from Pega Version 7.1.5

There are some unique configurations of the newly enhanced pxDisplayStages gadget that can lead to case type "Stages and Steps" appearing more than once or not at all.  In the event that your application experiences one of these scenarios, the recommended work around is to relocate the gadget:

  • Add pxDisplayStages to the pyCaseContainer section (or equivalent)
  • Remove pxDisplayStages from the pyCaseActionArea section (or equivalent).

DB2-LUW database logfile size increase

Valid from Pega Version 7.1.5

This issue applies to DB2-LUW database platforms only.
 

To avoid running out of logfile space due to large transaction sets during the rule base load of a Pega 7.1.x install, upgrade, or maintenance level update, systems supported by a DB2-LUW database platform should increase the LOGFILSIZ parameter to at least 4096 pages from the default size of 1000 pages.

After the size has been increased, restart the database to ensure that the new setting is loaded into the database correctly.

Text Input control number type does not validate

Valid from Pega Version 7.1.5

When a Text Input control type is set to "Number" in the Presentation tab:

  • Validation does not trigger and the field is blanked out when a user submits the form.
  • If a value other than a number is entered, the browser sends an empty value, and the value is not validated.
  • In the Clipboard, the field value displays as empty.
  • If the field is required, the validation displays.

This issue occurs when using both the Chrome and Safari web browsers, and is a result of browser behavior for the HTML5 type=“number”. To fix this issue when using these browsers, do not use the "Number" type in Presentation tab of a Text Input control. Instead, the type should be set to "Text".

Need to run script before updating Multitenant systems

Valid from Pega Version 7.1.5

When updating or upgrading a Multitenant system from Pega 7.1.5 or 7.1.6 to Pega 7.1.7, if that system uses either an Oracle or a PostgreSQL database, you may encounter the error:

“Table must be empty to add column.”

The Multitenant architecture requires an additional column on a number of the PRPC database tables (“pzTenantID”). In Pega 7.1.7, two additional PRPC tables were tenant-qualified: pc_schedule_task and pr_index_schedule_task. The Multitenant column is added to these tables by the update/upgrade process. However, Oracle and PostgreSQL do not allow the addition of a non-null column to an existing table unless the table is empty, so updating or upgrading systems on those databases displays the error detailed above.

To avoid this error, before beginning the update or upgrade, it is necessary to run a script:

  • OracleOracleMTupgrade.sql
  • PostgreSQLPostgresMTupgrade.sql

For updates, these scripts are located in the /scripts/ddl directory.

For upgrades, these scripts are located in the /Resourcekit/AdditionalUpgradeScripts directory.

Unclear error message when saving shared class instance in tenant layer

Valid from Pega Version 7.1.5

If you attempt to save a shared class instance from the tenant layer, Pega 7 displays this message:

This record has x errors. Save Failed: There was a problem saving an instance of class: Error Code: <none> SQL State: <none> Message: <none>

You cannot save a shared instance from the tenant layer if that instance cannot be overridden.

Customizations to the prlogging.xml file must be manually ported after upgrade

Valid from Pega Version 7.3

As a result of the upgrade from the Apache Log4j 1 logging service to the Apache Log4j 2 logging service, the name of the logging configuration file has changed from prlogging.xml to prlog4j2.xml and the format of the file has changed considerably. If you customized your prlogging.xml file, port the customizations to the new prlog4j2.xml file. If you do not port the changes, the Pega® Platform uses the default prlog4j2.xml file and disregards your customized prlogging.xml file.

For more information about customizing your log files, see the Apache Log4j 2 documentation.

Socket server has changed for remote logging

Valid from Pega Version 7.3

As a result of the upgrade from the Apache Log4j 1 logging service to the Apache Log4j 2 logging service, the socket server that is used for remote logging has changed from the Log4j remote logging package with the LogFactor5 log analysis tool to TcpSocketServer. If you use remote logging, update your socket server to TcpSocketServer. For more information, see Installing and using remote logging.