Skip to main content

Published Release Notes

Find release notes for the selected Pega Version and Capability

Browse resolved issues for Platform releases.

This documentation is for non-current versions of Pega Platform. For current release notes, go here.

Change logic does not work in Report Editor

Valid from Pega Version 7.1.2

The Report Editor​ change logic button does not work. As a workaround, use the rule form to change the logic.

Slow WebSphere performance on Mac platforms

Valid from Pega Version 7.1.2

Use the following JVM setting to improve WebSphere performance on Mac platforms:

-Djava.net.preferIPv4Stack=true

Split schema systems require additional privileges

Valid from Pega Version 7.1.2

On Oracle split schema systems, add the following database privileges:

  • Grant DROP ANY INDEX to the Admin User.
  • Grant UNLIMITED TABLESPACE to the Rules User.

Use the Oracle Enterprise Manager to add these privileges or refer to the 7.1.3 Upgrade and Installation guides for Oracle.

Node description cannot match application server node name

Valid from Pega Version 6.3 SP1

A node's Short Description should not be the same value as the application server node name. If the node's Short Description is changed to be the same value as the application server node name, then the node description is automatically changed back to the original value after a system restart.

Discontinued support for list view and summary view rules

Valid from Pega Version 7.2

The list view rule and the summary view rule are deprecated, and support for these rules has been discontinued. Existing list view and summary view reports will continue to work on supported browsers. However, the last version of Internet Explorer that list view and summary view rules support is Internet Explorer 11.

You cannot create new list view or summary view reports. Instead, create list reports and summarized reports by using the report definition rule. To prevent display issues, re-create the custom list view and summary view reports that you need as report definition reports.

Label changes to field types in Case Designer

Valid from Pega Version 7.2

The following field types have been renamed in Case Designer to be consistent with Data Designer and other areas of the Pega 7 Platform.

Label in previous versionsLabel in Pega 7.2
TextText (single line)
Text (multiple lines)Text (paragraph)
Check boxBoolean
Date and timeDate & time
DateDate only
Drop downPicklist
Number (integer)Integer
Number (decimal)Decimal

Users who upgrade from versions prior to Pega 7.2 do not have to take any action because the label changes are cosmetic and do not affect the underlying controls or property types that support form building.

For more information about the field types that you can use when building a form, see Storage and display of single-value fields.

Process Outline view is unavailable

Valid from Pega Version 7.2

Process Outline view is no longer available as of this release. Use Case Designer instead to configure your processes. For advanced options, you can open the underlying flow for a process in Process Modeler.

For more information, see Designing a case type and Diagram tab on the Flow form.

New location for case-type settings

Valid from Pega Version 7.2

The configuration options for case-type settings have been moved from the property panel to the Settings tab in Case Designer. This change separates behavioral settings from life-cycle settings so that you can stay focused as you design your case types.

For more information, see Configuring case-type behavior.

No private posts in new Pulse gadget

Valid from Pega Version 7.2

The new Pulse gadget does not support private posts. When you upgrade to the new gadget, any private posts of the following types that you created by using the previous version of the gadget become public.

  • Operator posts
  • Case posts
  • Posts that used the generic pxPostMessage API with private posts enabled
  • Posts that used the Pulse smart shape in PRPC 6.3 or earlier with private posts enabled

For more information about the new Pulse gadgets for developers, Pulse gadgets and custom APIs.

For more information about the using the new Pulse gadget, see Communicating with Pulse.

Column Populator utility documentation out of date for prior versions

Valid from Pega Version 7.2

The documentation for using the Column Populator utility to populate newly exposed database columns is out of date for Pega 7 Platform versions prior to 7.2. For all Pega 7 versions, refer to the Pega 7.2 help documentation for instructions about how to use this utility.

We'd prefer it if you saw us at our best.

Pega.com is not optimized for Internet Explorer. For the optimal experience, please use:

Close Deprecation Notice
Contact us