Skip to main content

Published Release Notes

Find release notes for the selected Pega Version and Capability

Browse resolved issues for Platform releases.

This documentation is for non-current versions of Pega Platform. For current release notes, go here.

Naming pattern changed for file data sets

Valid from Pega Version 8.6.3

File data sets are used to import from and export data to a file repository. In case of data export, prior to version 8.6.3, the first file exported had the same file name that was provided by the user in the data set, and any subsequent file exported to the repository had a unique identifier appended to it. Starting in Pega Platform version 8.6.3, each file has a unique identifier, automatically generated based on the data flow node, thread ID, and timestamp.

Upgrade impact

If your process to consume output files expects files with a specific name, it may not be able to process the resulting files correctly.

What steps are required to update the application to be compatible with this change?

If you have configured the process before updating to Pega Platform version 8.6.3, but the exported files are no longer recognized by downstream processing logic after the upgrade, ensure that the downstream tool is configured to recognize the files by a pattern rather than the full name. For example, when referring to files exported to the repository, use the * character to indicate a pattern instead of using the full file name. For example, use Export*.csv to refer to the files.

Flow rules not supported in IE8

Valid from Pega Version 7.1.1

In versions prior to 7.1.2, flow rules do not open in Internet Explorer 8 (IE8). Upgrade your system to the latest version of PRPC or access flows from another supported browser.

Turn off saved connections in WebLogic

Valid from Pega Version 7.1.1

PRPC caches connections in thread-local storage. When using a WebLogic application server, set database/savedconnections to FALSE to avoid incorrectly saved, container-managed transactions. You can make this update through JNDI settings or by adding an entry to the prconfig.xml, for example:

<env name="database/savedconnections" value="false" />

Remove JVM settings from prior installations

Valid from Pega Version 7.1.1

JVM memory settings ​defined in the setupDatabase.properties file to support a prior installation need to be removed. 

Memory settings are now handled by the installation program. Duplicating these settings may cause installation or upgrade failures. 

Automated Unit Testing is unavailable

Valid from Pega Version 7.1.1

Automated Unit Testing (AUT) is unavailable in 7.1.1 - 7.1.5.

Starting in 7.1.6, users can access AUT features from supported browser versions of IE.

Privilege required for Recent Explorer

Valid from Pega Version 7.1.1

Users with custom roles defined must add the pxUpdateRecents privilege to see work in the Recent Items Explorer. 

IE8 hangs on large imports

Valid from Pega Version 7.1.1

IE8 users may experience a hung process when running the Designer Studio > Application > Distribution > Import wizard. This issue is related to low-capacity networks and large (300+ MB) archive files.

Although the processing symbol prevents you from proceeding to the next step in the wizard, the file is still imported to the server. As a workaround, you can:

  1. Wait approximately eight minutes for the file to import.
  2. Close and restart the wizard.
  3. Click Next to skip the upload step.
  4. Select the name of your file from the list of import files.
  5. Complete the remaining steps in the wizard.

Required DB2 settings for LUW and z/OS

Valid from Pega Version 7.1.1

Installations on DB2 databases for LUW and z/OS require a minimum logging file size (4096) and a default table space page size (32K).

To set the table space page size to 32K:

  1. Stop the system.
  2. Rename one table (“TableX”) to backup (“TableXBackup”).
  3. Create a new table space that uses a 32K page size.
  4. Copy “TableXBackup” to “TableX” in the new table space.
  5. Restart the system and test to verify there are no issues.
  6. Drop the backup table (or keep it for future reference).

Additional information is available in the "Adjusting the log space size in upgraded databases" article: https://pic.dhe.ibm.com/infocenter/db2luw/v9r7/index.jsp?topic=%2Fcom.ibm.db2.luw.qb.upgrade.doc%2Fdoc%2Ft0023289.html

No direct upgrade to multitenant setup

Valid from Pega Version 7.1.1

It is not possible to upgrade directly to a multi-tenant setup. A Pega 7 application may be exported and then imported into a multi-tenant system, with the administrator making the decision as to whether this then becomes a tenant system or a shared system.

 

Applications developed in versions prior to Pega 7 must be upgraded to a Pega 7 standard system, and then exported and imported into a multi-tenant system. See the Multitenancy Administration Guide for full details.

Use standard Developer portal

Valid from Pega Version 7.1.1

Customized versions of the Developer portal rely on legacy components and are not supported.

To avoid backwards compatibility issues, update your access group to point to the standard Developer portal prior to upgrade.

We'd prefer it if you saw us at our best.

Pega.com is not optimized for Internet Explorer. For the optimal experience, please use:

Close Deprecation Notice
Contact us