WSDL generation error prevents invocation of SOAP services

Valid from Pega Version 8.4.2

Status

A Known Issue was introduced in the 8.4.2 Pega Platform patch release, which impacts both upgrades and new installations of that version.

Description

Due to changes introduced in the SOAP functionality for the case-mismatch error in SR-D98509/INC-119725, the WSDL is being generated for SOAP services with an incorrectly-capitalized element, which prevents the service from being invoked.  The element should be “name” instead of “Name”.

Workaround

Clients must perform the following workaround after they define a new SOAP connector in Pega Platform:

  1. To download the WSDL from Pega Platform:
    1. After using the SOAP Wizard (Dev Studio > Configure > Integration > Services > Service Wizard) the WSDL URL is shown at the bottom right of the Dev Studio screen.
    2. Click the URL to display the XML.
    3. Save the WSDL file to your local system.
  2. In the text editor of your choice, modify "Name" to "name" in every <element “name” = … > tag in the WDSL.
  3. Save your changes to the local file.
  4. To reload the WSDL into Pega Platform:
    1. In Dev Studio, open the Configure menu.
    2. Select Integration > Connectors > Create SOAP Integration.
    3. In the New SOAP integration wizard, select Upload WSDL from File.
    4. Complete the upload using the wizard prompts.

This is a design-time issue, not a run-time issue; therefore, clients only have to perform this workaround process once. Existing SOAP services should not be impacted; however, if clients modify an existing SOAP service definition by re-running the wizard, clients must reapply the workaround for Pega Platform to recognize the SOAP definition changes.  

Resolution

This issue will be addressed in the Pega Platform Patch Release 8.4.3.  Clients who upgrade to that version or later should not see this issue.

DCO and PMF integration is unavailable

Valid from Pega Version 7.1.5

DCO and PMF integration functionality is not available in this release. Related project management controls have been removed from the following:

  • System Settings landing page (Designer Studio > System > Settings > Project Management)
  • Application Profile landing page (Designer Studio > Application > Profile > Specifications)
  • Add/Edit Specification dialog

Restricted SMA access

Valid from Pega Version 7.1.5

System Management Application (SMA) remote connections are not supported on JBoss EAP 6.x. This means SMA users may only monitor locally connected systems. Ensure that the "Local JVM Connection..." option is selected when configuring PRPC nodes:

Stages and Steps may not appear as expected

Valid from Pega Version 7.1.5

There are some unique configurations of the newly enhanced pxDisplayStages gadget that can lead to case type "Stages and Steps" appearing more than once or not at all.  In the event that your application experiences one of these scenarios, the recommended work around is to relocate the gadget:

  • Add pxDisplayStages to the pyCaseContainer section (or equivalent)
  • Remove pxDisplayStages from the pyCaseActionArea section (or equivalent).

Text Input control number type does not validate

Valid from Pega Version 7.1.5

When a Text Input control type is set to "Number" in the Presentation tab:

  • Validation does not trigger and the field is blanked out when a user submits the form.
  • If a value other than a number is entered, the browser sends an empty value, and the value is not validated.
  • In the Clipboard, the field value displays as empty.
  • If the field is required, the validation displays.

This issue occurs when using both the Chrome and Safari web browsers, and is a result of browser behavior for the HTML5 type=“number”. To fix this issue when using these browsers, do not use the "Number" type in Presentation tab of a Text Input control. Instead, the type should be set to "Text".

Unclear error message when saving shared class instance in tenant layer

Valid from Pega Version 7.1.5

If you attempt to save a shared class instance from the tenant layer, Pega 7 displays this message:

This record has x errors. Save Failed: There was a problem saving an instance of class: Error Code: <none> SQL State: <none> Message: <none>

You cannot save a shared instance from the tenant layer if that instance cannot be overridden.

Node description cannot match application server node name

Valid from Pega Version 6.3 SP1

A node's Short Description should not be the same value as the application server node name. If the node's Short Description is changed to be the same value as the application server node name, then the node description is automatically changed back to the original value after a system restart.

High number of busy waits when using Oracle SecureFiles

Valid from Pega Version 7.2.1

You might experience a high number of buffer busy waits when using Oracle SecureFiles for BLOB storage. An Oracle buffer busy wait occurs when a session cannot access a database block in the buffer cache, because another session is either reading the block into the buffer or changing the buffer. As a best practice, use Oracle 11.2.0.4 or later, because earlier versions have more problems with SecureFiles. In addition, to minimize the number of busy waits, set the hidden Oracle parameter _securefiles_concurrency_estimate to 50, and partition the table by using a composite range hash partition that is based on the pxCreateDateTime and pzInskey columns.

For more information, see Troubleshooting: High number of busy waits when using Oracle SecureFiles.

Email approval and instantiation not supported on multitenant systems

Valid from Pega Version 7.2.1

The Enable email approval check box appears on the General tab of an approval step in Case Designer in multitenant systems. It also appears on the Approval shape in Designer Studio. In addition, in Designer Studio, the Settings tab in Case Designer displays the option to configure email instantiation. However, because configuring email listeners is not supported on multitenant systems, you cannot enable email approval or email instantiation.

Ignore locale settings requires refresh after server restarts

Valid from Pega Version 7.2.1

The Ignore locale check box in operator preferences is selected to display Designer Studio in U.S. English. After a server restarts, screens initially ignore this setting. When the screen is refreshed or reopened, the screen is rendered as expected.