Skip to main content

Published Release Notes

Find release notes for the selected Pega Version and Capability

Browse resolved issues for Platform releases.

This documentation is for non-current versions of Pega Platform. For current release notes, go here.

Data synchronization does not resume after mobile app restart

Valid from Pega Version 8.3

If an offline-enabled mobile app that you build with Pega Infinity Mobile Client is stopped during an initial data synchronization session, the data synchronization does not resume when the mobile app is restarted. Users must not stop the mobile app before initial data synchronization finishes.

For more information about data synchronization, see Offline capability and Guidelines for creating an offline-enabled application.

WSDL generation error prevents invocation of SOAP services

Valid from Pega Version 8.4.2

Status

A Known Issue was introduced in the 8.4.2 Pega Platform patch release, which impacts both upgrades and new installations of that version.

Description

Due to changes introduced in the SOAP functionality for the case-mismatch error in SR-D98509/INC-119725, the WSDL is being generated for SOAP services with an incorrectly-capitalized element, which prevents the service from being invoked.  The element should be “name” instead of “Name”.

Workaround

Clients must perform the following workaround after they define a new SOAP connector in Pega Platform:

  1. To download the WSDL from Pega Platform:
    1. After using the SOAP Wizard (Dev Studio > Configure > Integration > Services > Service Wizard) the WSDL URL is shown at the bottom right of the Dev Studio screen.
    2. Click the URL to display the XML.
    3. Save the WSDL file to your local system.
  2. In the text editor of your choice, modify "Name" to "name" in every <element “name” = … > tag in the WDSL.
  3. Save your changes to the local file.
  4. To reload the WSDL into Pega Platform:
    1. In Dev Studio, open the Configure menu.
    2. Select Integration > Connectors > Create SOAP Integration.
    3. In the New SOAP integration wizard, select Upload WSDL from File.
    4. Complete the upload using the wizard prompts.

This is a design-time issue, not a run-time issue; therefore, clients only have to perform this workaround process once. Existing SOAP services should not be impacted; however, if clients modify an existing SOAP service definition by re-running the wizard, clients must reapply the workaround for Pega Platform to recognize the SOAP definition changes.  

Resolution

This issue will be addressed in the Pega Platform Patch Release 8.4.3.  Clients who upgrade to that version or later should not see this issue.

Source field not displaying in data transform

Valid from Pega Version 7.1.4

On the Data Transform rule form when using the Update Page action, if the Relation value is updated to “with values from”, the Source field will not be displayed.

(Note that for existing data transforms where the Source field has already been completed, this situation should not occur.)

Workaround

  1. Below is a data transform that has been configured to use Update Page.
    DataTransform1.jpg
  2. If a user were to choose an alternate source by updating the ‘with values from’ Relation value, they would not be prompted to provide a page name in the Source field.
    DataTransform2.jpg
  3. At this point, to be able to enter the Source page value, the user has to save the rule, which results in an error because the source page value is blank. This causes the field to appear.
    DataTransform3.jpg
  4. Once the field has appeared, the Source page value can be provided, and the form can be saved successfully.
    DataTransform4.jpg

Required Oracle optimization parameter

Valid from Pega Version 7.1.3

To optimize performance, set the Oracle parameter optimizer_index_cost_adj to a value between 20 and 25. If this value is not set, the system can run exceedingly slowly, potentially blocking users from login.

Turn off saved connections in WebLogic

Valid from Pega Version 7.1.1

PRPC caches connections in thread-local storage. When using a WebLogic application server, set database/savedconnections to FALSE to avoid incorrectly saved, container-managed transactions. You can make this update through JNDI settings or by adding an entry to the prconfig.xml, for example:

<env name="database/savedconnections" value="false" />

Automated Unit Testing is unavailable

Valid from Pega Version 7.1.1

Automated Unit Testing (AUT) is unavailable in 7.1.1 - 7.1.5.

Starting in 7.1.6, users can access AUT features from supported browser versions of IE.

IE8 hangs on large imports

Valid from Pega Version 7.1.1

IE8 users may experience a hung process when running the Designer Studio > Application > Distribution > Import wizard. This issue is related to low-capacity networks and large (300+ MB) archive files.

Although the processing symbol prevents you from proceeding to the next step in the wizard, the file is still imported to the server. As a workaround, you can:

  1. Wait approximately eight minutes for the file to import.
  2. Close and restart the wizard.
  3. Click Next to skip the upload step.
  4. Select the name of your file from the list of import files.
  5. Complete the remaining steps in the wizard.

Synchronized database and application server settings

Valid from Pega Version 7.1.3

Configure your database and application server to use the same time zone and character encoding to avoid conflicts.

Required DB2 settings

Valid from Pega Version 7.1.1

For customers using the DB2 Version 4 drivers (“db2jcc4.jar”), it is necessary to set the custom connection property useJDBC4ColumnNameAndLabelSemantics to “false”.   

For customers using DB2 with WebSphere, the useJDBC4ColumnNameAndLabelSemantics property in the DB2 data source needs to be changed from a Boolean to an Integer and set to "2". 

DCO and PMF integration is unavailable

Valid from Pega Version 7.1.5

DCO and PMF integration functionality is not available in this release. Related project management controls have been removed from the following:

  • System Settings landing page (Designer Studio > System > Settings > Project Management)
  • Application Profile landing page (Designer Studio > Application > Profile > Specifications)
  • Add/Edit Specification dialog

We'd prefer it if you saw us at our best.

Pega.com is not optimized for Internet Explorer. For the optimal experience, please use:

Close Deprecation Notice
Contact us