INC-152776 · Issue 621244
Check added for HTML and linefeed combined in email
Resolved in Pega Version 8.5.3
In the Interaction right hand pane Email triage widget, additional line breaks were seen when displaying email message data that contained table tags. This was a missed use case for email which contains both HTML and '\n', which resulted in the system replacing '\n' with </br>. This has been resolved by adding a check whether the content has HTML tags which will avoid the replacement.
INC-156422 · Issue 617382
Updated email triage case creation to avoid unique key issue
Resolved in Pega Version 8.5.3
After upgrade, when the email listener queued the case and an agent picked up the queued item to create an Email Triage Case and then the interaction case, trying to commit the case failed with a Unique Key violation. Investigation traced this to the system trying to insert the record into the PC_WORK_TRIAGE table twice due to a timing issue in the workobject commit. This has been resolved.
SR-A92680 · Issue 263151
Removed duplicate repeat grid header
Resolved in Pega Version 7.3
An extra Grid Header Title was created when allow refresh on update was checked in a repeat grid configured for row editing via modal dialog. This was due to a place holder div error, and has been corrected.
SR-B385 · Issue 270797
ASCII characters properly displayed in dynamic layout headers
Resolved in Pega Version 7.3
When using a field value that contains special characters like + and = to display the header value of a dynamic layout the characters were being converted to their encoded ASCII characters on screen (ex [&] instead of [&]). This was traced to the Field Value text being encoded twice, and the GridHeaderElements function has been updated to correct this.
SR-A100782 · Issue 272266
Siteminder block resolved for DPParams containing double quotes
Resolved in Pega Version 7.3
Due to the DPParams being transmitted in JSON format, using the Siteminder CSSChecking parameter set to yes with BadCSSChars containing "%22" caused the " (double quotes) that surround the name value pairs to trigger a Siteminder block. To resolve this, the system will pass the DPParams in the post body instead of sending it in the query string.
SR-A101144 · Issue 272239
Error message clear after bad row deleted
Resolved in Pega Version 7.3
Error messages were not clearing even after deleting the row which caused the error. This has been corrected.
SR-A101500 · Issue 279633
Menubar Object memory leak repaired
Resolved in Pega Version 7.3
A memory leak has been resolved by eliminating unnecessary DesktopMouseClick events when creating a new old-Menubar object.
SR-A101500 · Issue 278178
Menubar Object memory leak repaired
Resolved in Pega Version 7.3
A memory leak has been resolved by eliminating unnecessary DesktopMouseClick events when creating a new old-Menubar object.
SR-A101675 · Issue 270578
Size to Content refresh updated
Resolved in Pega Version 7.3
A expandable grid with a text area and button as columns in it was not correctly calculating the size after refreshing. An explicit call to the resizeHarnessActual has been added to ensure expected behavior.
SR-A103192 · Issue 271775
ReadOnly radiobutton display fixed for null value
Resolved in Pega Version 7.3
When a radiobutton control was set ReadOnly, "--" was not displaying as expected when the property did not contain any value. Instead, the radio button values were displayed as empty. This was caused by a missing span tag element for read only mode, and has been fixed.