Skip to main content

Completed onChange will reset FileInput value to null

When attaching a file using the "Select File" button, it was not possible to attach the same file after deleting it. Re-attaching the file worked as expected when using Drag and Drop. Investigation showed that the onchange event occurred only when the value of an element was changed, so in this case trying to attach the same file did not change the value of the element and did not fire the onchange.

TemplateButton field correctly set read-only

When a control was added to a section using the DX API, a pyTemplateButton field was added to the XML definition of the section with read-only set to 'false'. This has been corrected so the pyTemplate Button field does not allow input.

Stale WorkSearchPreference data cleared when switching apps

The D_pyWorkSearchPreferences data page data was not refreshing while switching between apps, causing stale data to be populated under the case search dropdown for all the applications after switching the application from one to another. This has been resolved by removing the D_pyWorkSearchPreferences data page as part of pzProcessApplicationSwitch.

FetchApplicationLogo modified to Filter by rule resolution

It was observed that the Report Definition rule "pzFetchApplicationLogo", referenced by Activity rule "pzLoadApplicationLogo", always returned the older version of the Binary File "webwb • pyapp-logo • svg" because it had been set to retrieve a maximum of one record and in this case the results were sorted in an order where the oldest record was at the top. As the Report Definition did not indicate any sorting, most DBMS were returning the results in no particular or predictable order. To resolve this, "Filter by rule resolution" has now been enabled for RD pzFetchApplicationLogo.

URL encryption modified for ShowAllOperators

In the control ShowAllOperators the call to pzEncryptURLActionString was introduced to encrypt URLs to avoid hijacking. The content of the URL relied on the pxRequestor.pxWorkGroup property which was resolved using pega:reference tags. This approach worked in versions below 8.x, but in higher versions the tags were not resolved at runtime and results were not displayed. To resolve this, the requestorWorkGroup will be treated as string and passed as parameter instead of using pega:reference tags.

Handling added for null requiredskillcount on assignment

If the property pxRequiredSkillCount was blank on an assignment when moved to a workbasket, it was never presented for Get Next Work. To resolve this, handling has been added which will change the null to 0 so the assignment is properly queued.

Handling added for null requiredskillcount on assignment

If the property pxRequiredSkillCount was blank on an assignment when moved to a workbasket, it was never presented for Get Next Work. To resolve this, handling has been added which will change the null to 0 so the assignment is properly queued.